2J2
TABLE XI-V. ELECTRICAL SYSTEM TROUBLESHOOTING (cont)
OIL warning light fails
Bulb burned out.
Replace.
to operate.
No current to sensor.
Check all wire segments
and connections.
Sensor activates at a
Replace.
to low setting.
Defective sensor.
Replace.
OIL warning light fails
Sensor activates at a
Replace.
to extinguish.
too high setting.
Sensor terminals
Remove material
bridged.
between terminals.
Defective sensor.
Replace.
OVER BOOST warning
Bulb burned out.
Replace.
fails to operate.
Circuit in manifold
Replace gauge.
pressure gauge
defective.
OVER BOOST warning
Press to test switch
Replace switch.
fails to extinguish.
shorted to ground.
Circuit in manifold
Replace gauge.
pressure gauge
defective.
VAC warning light fails
Bulb burned out.
Replace.
to operate.
No current to sensor.
Check all wire segments
and connections.
Trouble
Cause
Remedy