2I20
TABLE XI-V. ELECTRICAL SYSTEM TROUBLESHOOTING (cont)
Excessive ammeter
Excessive resistance in
Check all connections and
fluctuation.
field circuit.
wire terminals in field
circuit for deterioration
such as loose binding posts,
broken wire strands at
terminals, etc. Tighten all
connections and replace
faulty terminals.
High field circuit
If problem persists, jump
resistance.
across terminals of the
following components
one at a time until the
faulty unit is isolated.
a. Field 5 amp (alternator)
circuit protector.
b. Alternator half of
master switch.
c. Overvoltage relay.
Defective voltage
Replace voltage regulator.
regulator.
Trouble
Cause
Remedy