2J1
TABLE XI-V. ELECTRICAL SYSTEM TROUBLESHOOTING (cont)
Battery freezes.
Discharged battery.
Replace.
Water added and battery
Always recharge battery for
not charged immediately.
1/2 hour following addition
of water in freezing weather.
Leaking battery jar.
Frozen.
Replace.
Battery polarity reversed.
Connected backwards on
Battery should be slowly
airplane or charger.
discharged completely and
then charged correctly and
tested.
Battery consumes excessive
Charging rate too high
Correct charging rate.
water.
(if in all cells).
Cracked jar (one cell
Replace battery.
only).
All warning lights fail
Blown fuse.
Replace the 5 amp fuse
to operate.
behind instrument panel.
No current from bus.
Check all wire segments,
connections, and the
receptacle at the left side
of the annunciator panel.
All the warning lights
Test switch grounded
Check terminals and
fail to extinguish after
out.
replace switch if
engine is running.
necessary.
Trouble
Cause
Remedy
Revised: 2/13/89
CHEROKEE ARROW III SERVICE MANUAL
ELECTRICAL SYSTEM
BATTERY (cont)
ANNUNCIATOR PANEL