PDP-425CMX
95
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Note 1 :
Temperature information is not actual temperature for A/D value from the temperature sensor IC.
Conversion expression: Temperature information (TEMP 0/TEMP 1)
×
1.255-50.44= temperature ( ºC )
Note 2 :
Maximum recording time is 279620 hours 16 minutes. When exceeded maximum recording time, reset to zero.
[QS2]: To acquire data on the panel operation information
Order
Data Contents
Size
Remarks
1
STX
1Byte
02hex
2
Command echo back
3Byte
QS2 (fixed)
3
Standby operation shift notice
1Byte
0: STB shift NG 1: STB shift OK
4
Main unit adjustment flag
1Byte
0: Adjustment is completed 1: Adjustment is not completed
5
Adjustment backup flag
1Byte
0: Exist 1: Nothing
6
PD information-1st
1Byte
0: no PD 2: POWER 3: SCAN 4: SCAN-5V 5: Y-DRV
6: Y-DC/DC 7: Y-SUS 8: ADRS 9: X-DRV A: X-DC/DC
B: X-SUS C: DC/DC conveter D: ASTRA PD
E: V-ADDRS F: Unknown
7
PD information-2nd
1Byte
8
Temperature information (TEMP0)
3Byte
Note 1
9
Temperature information (TEMP1)
3Byte
Note 1
10
SD category
1Byte
0: no SD 1: ASTRA communication error 2: IIC communication error
3: RST2 abnormality 4: Temperature abnormality 6: no SD
11
SD subcategory
1Byte
0: There is no subcategory 1: General purpose EEPROM
2: BACKUP EEPROM 3: DAC IC 4: AUDIO 5: DVI 6: TEMP IC
12
Operating state with SD
1Byte
1: Normally 2: Relay OFF completion 3: Warning
13
HOUR METER
6Byte
000000 - 279620 (time) Note 2
2Byte
00 - 59 (minutes) Note 2
14
MASK display state
1Byte
0: MASK OFF 1: MASK ON
15
Aging state
1Byte
16
Check sum
2Byte
17
ETX
1Byte
03hex
[QIP]: To acquire data on the other panel information
Order
Data Contents
Size
Remarks
1
STX
1Byte
02hex
2
Command echo back
3Byte
QIP (fixed)
3
Serial number
15Byte
15 columns of character string
4
HOUR METER
6Byte
As the same contents as item 13 of QS2 command
2Byte
5
BACKUP HOUR METER
6Byte
As the same contents as item 13 of QS2 command
2Byte
6
POWER ON COUNTER
8Byte
00000000 - 99999999
14
Check sum
2Byte
15
ETX
1Byte
03hex
[QAJ]: To acquire data on the panel adjustment value
Order
Data Contents
Size
Remarks
1
STX
1Byte
02hex
2
Command echo back
3Byte
QAJ (fixed)
3
V-SUS adjustment value
3Byte
000 - 255
4
V-OFT adjustment value
3Byte
000 - 255
5
V-RST-P adjustment value
3Byte
000 - 255
6
XSB adjustment value
3Byte
120 - 136
7
YSB adjustment value
3Byte
120 - 136
8
YTG adjustment value
3Byte
120 - 136
9
YTW adjustment value
3Byte
120 - 136
10
RSW adjustment value
3Byte
120 - 136
11
R-RIVICE setting value
1Byte
0 - 7
12
G-RIVICE setting value
1Byte
0 - 7
13
B-RIVICE setting value
1Byte
0 - 7
14
Check sum
2Byte
15
ETX
1Byte
03hex
Summary of Contents for PDP-42MXE10
Page 9: ...PDP 425CMX 9 5 6 7 8 5 6 7 8 C D F A B E ...
Page 27: ...PDP 425CMX 27 5 6 7 8 5 6 7 8 C D F A B E ...
Page 37: ...PDP 425CMX 37 5 6 7 8 5 6 7 8 C D F A B E ...
Page 129: ...PDP 425CMX 129 5 6 7 8 5 6 7 8 C D F A B E ...
Page 132: ...PDP 425CMX 132 1 2 3 4 1 2 3 4 C D F A B E MAIN PWB CONNECTOR WAVE FORM POINT SIDE B ...