Technical Data
Deactivation
If the optocoupler is energized, the motor current is
deactivated.
Deselect
Pulse inhibit, when current flows through the optocoupler.
If the input is
not
connected, the power stage is ready for
work.
Reset
A reset causes resetting of all error messages.
Waiting time after cut off the Reset signal: about 500 msec
Outputs
Opto-decoupled, type Open-Collector Darlington
I
max
= 20 mA, U
max
= 30 V, UCE
sat
at 20 mA < 1 V
Ready
The CLD
+
is ready to operate, if the output „Ready“ is closed
(current is flowing).
The input "Deactivation" must not be energized.
Error
The common error output opens in case of the following error
signals: under voltage or over temperature.
To avoid damages, the drive is deactivated at the same time.