Manual CLD
+
7. Always switch off the supply voltage if you connect or disconnect any wires or
connectors at the CLD
+
.
Most important:
Do not unplug the motor connector while powered.
Danger of electric arcing.
8. Voltages connected to the signal inputs and outputs (X3, X4 connectors)
should be safely separated from mains. The maximum voltage against
protective earth must not exceed 60 V
DC
.
9. Clearing the DEACTIVATION input or deselection with the DESELECT input
or RESET is no protective separation in the emergency case.
The voltage supply has to be interrupted for switching off the drive safely.
10. The surface of the CLD
+
may reach temperatures of more than 70 °C.
Danger of injury if touching the surface!
MA 2112-A002 GB
14