Manual CLD
+
7.2.6 Deactivation
If the input optocoupler is energized, the motor current is switched off.
This input is useful, for instance, during maintenance operations to switch the power stage
off, without having to disconnect it physically from the mains. It is possible now to rotate
the motor by hand slowly.
WARNING!
The „Deactivation“ input is not on conformance with the professional
emergency stop circuit requirements!
7.2.7 Deselect
If the input optocoupler is energized, the pulse inhibit is active.
If the input is not connected, the CLD
+
is ready for work.
7.2.8 Reset
If the input opto coupler is energized, all error signals are reset and the monitoring circuits
are initialized.
After cut-off the reset signal, the power stage enables the ready signal after approximately
500 msec.
Remark:
Reset can also be activated by the menu item
RESET
in the Setup menu.
MA 2112-A002 GB
28
Summary of Contents for 10010115
Page 1: ...Manual 2112 A002 GB CLD Linear Power Stage For Stepper Motor with Plain Text Display...
Page 2: ......
Page 10: ...Manual CLD 1 4 Schematic Diagram Fig 3 Schematic diagram CLD MA 2112 A002 GB 8...
Page 19: ...phytron Fig 5 Mountaing kits 17 MA 2112 A002 GB...
Page 33: ...phytron 8 The Menu Fig 15 Structogram of the menu 31 MA 2112 A002 GB...
Page 49: ...phytron Appendix C Declarations of Conformity 47 MA 2112 A002 GB...
Page 50: ...Manual CLD MA 2112 A002 GB 48...
Page 53: ......
Page 54: ......
Page 55: ......