phyCARD-M [PCA-A-M1-xxx]
26
©
PHYTEC Messtechnik GmbH 2010 L-750e_1
Jumper
Description
Type
Chapter
J13
J13 allows to attach a programming voltage to the IC
Identification Module (IIM)
for programming
and/or overriding identification and control
information stored in on-chip fuse elements
.
0R
(0402
)
open
VDD_FUSE not connected
closed
Only close Jumper when burning of fuses
is required
7.3.2
J21
J21 selects rising, or falling edge strobe for the LVDS
Deserializer at U5 used for the display connectivity of
the phyCARD-M
10k
(0805
)
1+2
rising edge strobe used for the LVDS
camera signals
2+3 fall
ing edge strobe used for the LVDS
camera signals
13.1
J22
J22 selects rising, or falling edge strobe for the LVDS
Transmitter at U4 used for the display connectivity of
the phyCARD-M.
10k
(0805
)
1+2
falling edge strobe used for the LVDS
display signals
2+3 ris
ing edge strobe used for the LVDS
display signals
12.1
Table 4:
Jumper settings