![Photon Focus DR1-D1312(IE)-G2 User Manual Download Page 68](http://html1.mh-extra.com/html/photon-focus/dr1-d1312-ie-g2/dr1-d1312-ie-g2_user-manual_1553526068.webp)
4 Functionality
MV1-D1312(IE/C)-80
MV1-D1312(IE/C)-80
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
50 ns
t
trigger
−
delay
0
0.84 s
t
burst
−
trigger
−
delay
0
0.84 s
t
burst
−
period
−
time
depends on camera settings
0.84 s
t
trigger
−
offset
(non burst mode)
200 ns
200 ns
t
trigger
−
offset
(burst mode)
250 ns
250 ns
t
exposure
10
µ
s
0.84 s
t
strobe
−
delay
600 ns
0.84 s
t
strobe
−
offset
(non burst mode)
200 ns
200 ns
t
strobe
−
offset
(burst mode)
250 ns
250 ns
t
strobe
−
duration
200 ns
0.84 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.14: Summary of timing parameters relevant in the external trigger mode using camera MV1-
D1312(IE/C)-80
66