![Photon Focus DR1-D1312(IE)-G2 User Manual Download Page 51](http://html1.mh-extra.com/html/photon-focus/dr1-d1312-ie-g2/dr1-d1312-ie-g2_user-manual_1553526051.webp)
There are no restrictions for the settings of the region of interest in y-direction
in the MV1-D1312(IE/C) camera series. The ROI settings in y-direction for the
DR1-D1312(IE)-200 camera is restricted to modulo 2.
Width
ROI-X (MV1-D1312(IE/C)-40)
ROI-X (MV1-D1312(IE/C)-80)
ROI-X (-100
2)
, -200
3)
)
288
512
not available
not available
320
480 ... 512
not available
not available
352
448 ... 512
not available
not available
384
416 ... 512
not available
not available
416
384 ... 512
448
not available
448
352 ... 512
416 ... 448
not available
480
320 ... 520
384 ... 448
not available
512
288 ... 512
352 ... 448
not available
544
256 ...512
320 ... 448
384
576
224 ... 512
288 ... 448
352 ... 384
608
192 ... 512
256 ... 448
320 ... 352
640
160 ... 512
224 ... 448
288 ... 384
672
128 ... 512
192 ... 448
256 ... 384
704
96 ... 512
160 ... 448
224 ... 384
736
64 ... 512
128 ... 448
192 ... 384
768
32 ... 512
96 ... 448
160 ... 384
800
0 ... 512
64 ... 448
128 ... 384
832
0 ... 480
32 ... 448
96 ... 384
864
0 ... 448
0 ... 448
64 ... 384
896
0 ... 416
0 ... 416
32 ... 384
...
...
...
...
1312
0
0
0
Table 4.7: Some possible ROI-X settings (Footnotes:
2)
MV1-D1312(IE/C)-100,
3)
DR1-D1312(IE)-200)
.
4.3 Reduction of Image Size
49
Summary of Contents for DR1-D1312(IE)-G2
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started GigE G2 Figure 2 3 PFInstaller components choice 12...
Page 96: ...4 Functionality 94...
Page 122: ...6 Software 120...
Page 128: ...8 Warranty 126...
Page 130: ...9 References 128...