![Photon Focus DR1-D1312(IE)-G2 User Manual Download Page 67](http://html1.mh-extra.com/html/photon-focus/dr1-d1312-ie-g2/dr1-d1312-ie-g2_user-manual_1553526067.webp)
MV1-D1312(IE/C)-40
MV1-D1312(IE/C)-40
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
100 ns
t
trigger
−
delay
0
1.68 s
t
burst
−
trigger
−
delay
0
1.68 s
t
burst
−
period
−
time
depends on camera settings
1.68 s
t
trigger
−
offset
(non burst mode)
400 ns
400 ns
t
trigger
−
offset
(burst mode)
500 ns
500 ns
t
exposure
10
µ
s
1.68 s
t
strobe
−
delay
0
1.68 s
t
strobe
−
offset
(non burst mode)
400 ns
400 ns
t
strobe
−
offset
(burst mode)
500 ns
500 ns
t
strobe
−
duration
200 ns
1.68 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.13: Summary of timing parameters relevant in the external trigger mode using camera MV1-
D1312(IE/C)-40