4 Functionality
0
50
100
150
200
250
300
Typical LinLog2 Response Curve − Varying Parameter Time1
Illumination Intensity
Output grey level (8 bit) [DN]
T1 = 840
T1 = 920
T1 = 960
T1 = 980
T1 = 999
Time2=1000, Value1=19, Value2=14
Figure 4.14: Response curve for different LinLog settings in LinLog2 mode
0
20
40
60
80
100
120
140
160
180
200
Typical LinLog2 Response Curve − Varying Parameter Time1
Illumination Intensity
Output grey level (8 bit) [DN]
T1 = 880
T1 = 900
T1 = 920
T1 = 940
T1 = 960
T1 = 980
T1 = 1000
Time2=1000, Value1=19, Value2=18
Figure 4.15: Response curve for different LinLog settings in LinLog2 mode