– 420 –
NWA-008845-001 Rev.5.0
32ch1007.fm
INTERNAL TONE/VOICE SIGNALING
PROGRAMMING
DESCRIPTION
DATA
To activate the Single-Digit Feature Access
Code feature, set the data for 050, 051, 069,
148 and 543 to “1”.
(1)
(2)
050: * Button as Switch Hook Flash.
1 : Ineffective
(1)
(2)
051: # Button as Switch Hook Flash.
1 : Ineffective
(1)
(2)
069: Single Digit Dialing on BT Connec-
tion
1 : Step Call
(1)
(2)
148: Same Last Digit Redialing on BT
Connection
1 : Ineffective
(1)
(2)
543: Step Call
1 : Allow
Provide the system with the Single-Digit Fea-
ture Access Code on RBT or Voice Call con-
nection.
(1)
(2)
156
0: Available
Specify if Voice Call is provided when calling
a D
term
is set to Voice First from a Single-Line
Telephone or a D
term
without an LCD.
(1)
(2)
270
0 : Not provided (Busy Tone)
1 : To provide
Provide the system with the Single-Digit Fea-
ture Access Code on BT connection.
(1)
(2)
208
0: Available
Specify whether the access codes of Single-
Digit Feature Access Code feature are fixed or
not.
[Series 3600 software required]
(1)
(2)
570
0 : Programmable Access Code
1 : Fixed Access Code
When using programmable access code
(CM08>570 is set to 0), assign the Single-
Digit Feature Access Code for the RBT con-
nection.
[Series 3600 software required]
•
(1)
(2)
Y=5
X: Access code (0-9, A (*), B (#))
1
: Internal Tone/Voice Signaling
NONE : Single-Digit Feature Access
Code is not available
START
CM08
CM20
A
JULY/01/2006
INTERNAL TONE/VOICE SIGNALING