– 130 –
NWA-008845-001 Rev.5.0
32ch1002.fm
BOSS/SECRETARY CALLING
PROGRAMMING
To set up the Secretary station with the D
term
:
DESCRIPTION
DATA
Assign the Secretary station to the required sta-
tion number.
•
(1)
(2)
Y=12
X-XXXXXXXX: My Line No. of Secre-
tary
0: Secretary station
If the Boss station is a Single-Line Telephone
with MW lamp, provide the Message Waiting
service to the Boss station.
•
(1)
(2)
Y=03
X-XXXXXXXX: Boss Station No.
0: To provide
Assign the Boss line key as a Secondary
Extension line to the Secretary’s D
term
.
•
(1)
(2)
Y=00
My Line No. of Sec
+ Key No.
X-XXXXXXXX: Boss Station No. /Boss
My Line No.
Assign the MW SET/MW RESET keys to the
Secretary’s D
term
, if needed.
•
(1)
(2)
Y=00
My Line No. of Sec
+ Key No.
F0040: MW Set
F0041: MW Reset
If the Boss station is a D
term
, assign a MW
Lamp to the Boss’ D
term
.
•
(1)
(2)
Y=00
My Line No. of Boss +
+ Key No.
F1005: MW Lamp
Assign the access code for MW Set/MW Reset
to the secretary’s D
term
, if required.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A040: MW Set
A041: MW Reset
Whether Message Waiting/Message Reminder
is reset (turning the MW Lamp off) irrespec-
tive of answering of calling station when the
called station calls to retrieve the message.
(1)
(2)
234
0 : Available
1 : Not available (Reset by answering of
calling station)
Specify the MW Lamp indication pattern for
D
term
.
(1)
(2)
294
0 : Flashing (60 IPM)
1 :
Steady lighting
START
CM13
CM90
,
,
,
CM20
CM08
A
BOSS/SECRETARY CALLING