– 681 –
NWA-008845-001 Rev.5.0
32ch1010.fm
DESCRIPTION
DATA
Assign the stored number to each Memory Slot
number.
•
(1)
(2)
Y=0
X YY Z
X : 0-3: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
Stored No.:
Outgoing Call Access Code (Maximum 4
digits) +
+ Called Party’s No. (Maxi-
mum 26 digits)
To set a pause into the stored No., enter “C”
(Fixed Pause=1.5 seconds) or “D” (Pro-
grammable Pause specified by CM41
Y=0>38) after desired digits.
NONE : No data
Assign the station name to be displayed to each
Memory Slot number, by character codes or
character.
•
(1)
(2)
Y=1
X YY Z
X : 0-3: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
XX...XX: Station Name Character Code
(Maximum 32 digits, 16 charac-
ters)
NONE : No data
See APPENDIX B:
Character Code Table
.
Page B2
•
(1)
(2)
Y=2
X YY Z
X : 0-3: 1000-Slot Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
XX...XX: Station Name Character
(Maximum 16 characters)
NONE : No data
A
CM74
,
END
JANUARY/20/2006
SYSTEM SPEED DIALING