– 792 –
NWA-008845-001 Rev.5.0
32ch2001.fm
• For Set Side (stations of SLT, sub line of D
term
or virtual line stations)
DESCRIPTION
DATA
Assign Service Restriction Class A to the re-
quired stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Do Not Disturb in Service Restriction
Class A assigned by CM12 Y=02.
•
(1)
(2)
Y=19
00-15: Service Restriction Class A assigned
by CM12 Y=02
0 : Restricted
1 : Allow
Assign Service Restriction Class C to the re-
quired stations.
•
(1)
(2)
Y=07
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
00-15 : Service Restriction Class C
Allow Do Not Disturb to be set in Service Re-
striction Class C assigned by CM12 Y=07.
•
(1)
(2)
Y=189
00-15: Service Restriction Class C assigned
by CM12 YY=07
0 : Allow
1 : Restricted
Provide Do Not Disturb feature to each tenant.
•
(1)
(2)
Y=19
00-63: Tenant No.
0 : Not provided
1 : To provide
Specify the Do Not Disturb Lamp Indication
on Line/Trunk/Feature keys of D
term
.
•
(1)
(2)
Y=62
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
0 : Not indicated
1 : Not used
2 : Do Not Disturb Lamp Indication
3 : Message Waiting Lamp Indication
START
CM12
CM15
CM12
CM15
CM65
CM12
END
NOVEMBER/15/2006
HOTEL SYSTEM PROGRAMMING
DO NOT DISTURB-HOTEL/MOTEL