– 185 –
NWA-008845-001 Rev.5.0
32ch1003.fm
STEP11:
As for the third CIR Trunk, restore the AP number X to Z by CM05 and by the SENSE switch.
Jump to STEP17 if no more CIR Trunks are provided.
STEP12:
Set the MB switch to ON (UP) on the third CIR Trunk with AP number Z.
STEP13:
As for the fourth CIR Trunk, change the AP number W to X by CM05 and by the SENSE
switch.
STEP14:
Set the SW1-1 through SW1-4 to ON on the fourth CIR Trunk.
Clear the memory for CMDC and CMDB by CMDB Y=90.
Set the SW1-1 through SW1-4 to OFF on the fourth CIR Trunk.
STEP15:
Load the office data saved in STEP1 by MAT.
STEP16:
As for the fourth CIR Trunk, restore the AP number X to W by CM05 and by the SENSE switch.
STEP17:
Set the MB switches to OFF (DOWN) on all the CIR Trunks.
HARDWARE REQUIRED
COT card (4COTG/8COTQ)
CIR card (4RSTC-A/4RSTC)
CALLER ID CLASS