– 99 –
NWA-008845-001 Rev.5.0
32ch1002.fm
CALL WAITING INDICATION-ACD
PROGRAMMING
To provide Call Waiting (CW) LEDs on the D
term
:
DESCRIPTION
DATA
Assign the incoming call to queuing mode
when all ACD stations are busy.
(1)
(2)
212
1 : Queuing
Specify the maximum number of queuing in
each ACD group for controlling call waiting
lamp of a D
term
.
(1)
(2)
15
01-99
: 1 call-99 calls
NONE : 1 call
NOTE:
Depending on the number of queuing station/trunk, lamp indication pattern on a D
term
is
different as shown below:
N=Number of queuing station/trunk
Assign the ACD Call Waiting Indication LED
to the required D
term
, as required.
•
(1)
(2)
Y=00
My Line No. +
+ Key No.
F1280-F1295: ACD Group 0-15
START
CM08
CM42
CONDITIONS
LAMP INDICATION
2nd Data=01
Steady on red irrespective of number of queuing station/trunk
1
≤
N<2nd Data (2nd Data
≠
01)
Steady on red
2nd Data
≤
N (2nd Data
≠
01)
Flashing red
CM90
,
END
AUTOMATIC CALL DISTRIBUTION (ACD)
CALL WAITING INDICATION-ACD