![Philips SOPHO 2000 IPS User Manual Download Page 371](http://html.mh-extra.com/html/philips/sopho-2000-ips/sopho-2000-ips_user-manual_321524371.webp)
– 353 –
NWA-008845-001 Rev.5.0
32ch1006.fm
• For Set Side (stations of SLT, sub line of D
term
or virtual line stations)
HARDWARE REQUIRED
To provide Do Not Disturb group set/cancel at specified timing in advance:
AP00-B/AP00-D card with MRCA program
DESCRIPTION
DATA
Assign Service Restriction Class A to the re-
quired stations.
•
(1)
(2)
Y=02
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow Do Not Disturb in Service Restriction
Class A assigned by CM12 Y=02.
•
(1)
(2)
Y=19
00-15: Service Restriction Class A assigned
by CM12 Y=02
0 : Restricted
1 : Allow
Assign Service Restriction Class C to the re-
quired stations.
•
(1)
(2)
Y=07
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
00-15 : Service Restriction Class C
Allow Do Not Disturb to be set in Service Re-
striction Class C assigned by CM12 Y=07.
•
(1)
(2)
Y=189
00-15: Service Restriction Class C assigned
by CM12 YY=07
0 : Allow
1 : Restricted
Provide Do Not Disturb feature to each tenant.
•
(1)
(2)
Y=19
00-63: Tenant No.
0 : Not provided
1 : To provide
Assign the Do Not Disturb Lamp Indication on
Line/Trunk/Feature keys of D
term
.
•
(1)
(2)
Y=62
X-XXXXXXXX: Station No./Sub Line
No./Virtual Line Station
No.
0 : Not indicated
1 : Not used
2 : Do Not Disturb Lamp Indication
3 : Message Waiting Lamp Indication
START
CM12
CM15
CM12
CM15
CM65
CM12
END
NOVEMBER/15/2006
DO NOT DISTURB