EXTERNAL PAGING WITH MEET-ME
PROGRAMMING
(1) To provide External Paging from stations
When one Paging trunk is connected with one AMP relay circuit.
DESCRIPTION
DATA
Assign the Paging Trunk (COT card and DK
card) to the required LEN.
NOTE 1:
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
000-763: LEN
D000-D255: COT card
E800-E831 : DK card
For PIM0/1 : E800-E807
For PIM2/3 : E808-E815
For PIM4/5 : E816-E823
For PIM6/7 : E824-E831
NOTE 2:
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface of MP card by setting
CM44.
Assign the Paging Trunk (COT card and DK
card) to the required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
D000-D255 : COT card
E800-E831
: DK card
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 2:
Circuit No. 3 of E831 is used for
built-in External Equipment In-
terface of MP card by setting
CM44.
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
(1)
(2)
700
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
START
CM10
CM14
CM08
A