• For MCI with AP00 (PN-AP00-B with AP00 program)
DESCRIPTION
DATA
Specify whether the text (Message Waiting
control text sending is available) is sent to the
VMS when the AP00 card is reset.
(1)
(2)
136
0 : To send
1 : Not sent
Specify the number of digits for station num-
ber in the message format to communicate
with the VMS.
(1)
(2)
137
0 : 6 digits
1 : 8 digits
Assign the attribute data, depending on the
port (Port 0-3) connected to the VMS.
(1)
(2)
See the following table.
See the following table.
NOTE 1:
For the Port 1 and Port 3, data speed 9600 bps cannot be set.
NOTE 2:
This data should be assigned depending on the attribute of the VMS.
NOTE 3:
To send the text to the VMS successively, assign the guard timer.
D
CMD000
CMD001
AP00 INITIAL
FIRST DATA (1)
MEANING
SECOND
DATA (2)
MEANING
PORT
0
PORT
1
PORT
2
PORT
3
20
24
28
32
Data speed
2/3/4/5
NOTE 1
1200/2400/4800/9600
bps
NOTE 2
21
25
29
33
Stop bit length
0 /1/2
1/1.5/2 bits
NOTE 2
22
26
30
34
Data length
0 /1
7/8 bits
NOTE 2
23
27
31
35
Parity
0 /1/2
None Parity/Even Par-
ity/Odd Parity
NOTE 2
80
100
120
140
Equipment Type
24
MCI
81
101
121
141
Priority for data processing
0
1st Priority
85
105
125
145
Station Address (SA)
48
0
86
106
126
146
Unit Address (UA)
33
!
89
109
129
149
Timer for detecting the end of block
5
512 ms.
98
118
138
158
Guard timer between texts
0
1
2
3
4
0-128 ms.
128-256 ms.
256-384 ms.
384-512 ms.
512-640 ms.
NOTE 3
E
MESSAGE CENTER INTERFACE (MCI)
PROGRAMMING