iXM-MV150F/iXM-MV100 Camera Systems
Installation Guide
Page 7
Table 1
: Exposure Sequence
3.2
Wiring a Control Cable for the iXM MV Camera
Table 2:
Control Cable Wiring
Typical Values
iXM MV100
iXM MV150F
T1
Trigger IN
SysRdy (Low)
2 ms
SysRdy (Low)
2 ms
T2
Trigger IN – Start exposure
30 ms
30 ms
T3
Start Exp – End Exp
T2 + Exposure time
T2 + Exposure time
T4
Trigger IN – SysRdy High
(Cycle time)
12bit pixel depth:
290ms + Exposure time
14bit pixel depth:
390ms + Exposure time
16bit pixel depth:
800ms + Exposure time
12bit pixel depth:
390ms + Exposure time
14bit pixel depth:
520ms + Exposure time
16bit pixel depth:
Exposure time
Pin Color
Name
Description
Direction
Level
Notes
1
Orange
Reserved
Reserved
Reserved
Reserved
Reserved
2
Green
System Ready
Camera ready for
next capture.
Out
VOH, min = 4.0V
(Io = -10uA)
VOL, max = 0.8V
(Io = 4mA)
5 Volt Level Pull up
resistor
47.5K Ohms to +5 V
3
Red
Black Reference
Control
Indicates a black
reference sequence
is required.
In
VIH, min = 2.4V
VIL, max = 0.8VtiF,
tiR < 1uSec
Isolated. Active low.
See “Understanding
page 8
4
Purple
Trigger In
Trigger the
new capture cycle
In
VIH, min = 2.4V
VIL, max = 0.8V
tiF, tiR < 1uSec
Active low.
(For manual triggering,
activate by short to
common signal,
otherwise leave floating)
5
Blue
Reserved
--
--
--
--
6
Yellow
Reserved
--
--
--
--
7
White
Light Trigger
Pulse
Marks start and stop
of exposure
Out
VOH min = 4.0V
(Io= -4mA)
VOL max = 0.8V
(Io= 4mA)
5 Volt Level
8
Gray
Reserved
Reserved
In
Short to pin 9
9
Black
Common
Common