iXM-MV150F/iXM-MV100 Camera Systems
Installation Guide
Page 8
Table 3
– Camera Control Cable Description
Table 2 above, describes the functionality of the wires in the iXM-MV Camera control cable; the
figures below show the wire numbering order.
Figure 1
: Control Cable Plug Pinout
Figure 2
: Control Socket Pinout
3.3
Understanding Black Reference
A Black Reference is an on-site camera calibration for the current camera settings and environmental
conditions.
It is recommended to perform a new Black Reference calibration whenever you change the exposure time by
more than 100ms, or whenever the camera temperature changes by more than 10
0
C.
To perform a new Black Reference, take an image while the camera is not exposed to light (
see details
below
).
VIL
Maximum voltage level that is interpreted as a ‘0’ by an input.
VIH
Minimum voltage level that is interpreted as a ‘1’ by an input.
VOL Guaranteed maximum voltage level that appears on output set to ‘0’.
VOH Guaranteed minimum voltage level that appears on output set to ‘1’.
VIT+ Input threshold voltage when the input voltage is rising;
VIT - Input threshold voltage when the input voltage is falling.