45
Operation with multiple internal WIDE SCSI units
The CYBERSTORM MKIII SCSI has to be connected to one of the middle plugs of the SCSI cable.
At every physical end of the WIDE SCSI cable a WIDE SCSI unit with activated terminators is
connected. Additional WIDE SCSI units with termination deactivated can be connected to free
plugs of the WIDE SCSI cable.
Operation with multiple internal Fast SCSI units
The CYBERSTORM MKIII SCSI has to be connected to one of the middle plugs of the SCSI cable.
One physical end of the WIDE SCSI cable is connected to an active terminator pack. The other
end of the WIDE SCSI cable is connected to a Fast SCSI cable using an adaptor WIDE->Fast. One
of the Fast SCSI units needs to be connected with activated termination to the other physical end
of the Fast SCSI cable. Additional Fast SCSI units with termination deactivated can be connected
to free plugs of the Fast SCSI cable.
Operation with internal Fast SCSI and WIDE SCSI units
The CYBERSTORM MKIII SCSI has to be connected to one of the middle plugs of the SCSI cable.
The WIDE SCSI unit has to be connected at the plug at the end of the internal WIDE SCSI cable
with termination activated. Additional WIDE SCSI units with termination deactivated can be
connected to free plugs of the WIDE SCSI cable. The other end of the WIDE SCSI cable is connec-
ted to a Fast SCSI cable using an adaptor WIDE->Fast. The adaptor used needs to terminate the