38.2 Change the direction of rotation of the mixing pump motor in case
of blockages in the hose 60Hz
1
2 5
Fig. 69: Change direction of rotation
60Hz
1. Turn the main switch (1) to position "0".
2.
Slide the metal bracket (2) in the opposite direction
.
3. Turn main switch (1) to position "I".
4. Turn the selector switch for the water pump (3) to position
”0“.
5. Turn the selector switch for the air compressor (4) to position
”0“.
6. Press the green push button (3) control voltage “ON”.
7. The yellow pilot lamp (6) for changing the direction of rotation
lights up.
8. Press the push button reverse direction of rotation (7).
9. Check the mortar pressure gauge if the mortar pressure has
lowered to "0 bar".
10. Turn the main switch (1) to position "0".
38.3 Blockage does not dislodge
2
1
Fig. 70: Mortar pressure gauge
DANGER!
Overpressure on the machine!
When opening machine parts they can open in an
uncontrolled manner and injure the operator.
Open the mortar hoses only when the pressure at the
mortar pressure gauge (1) has dropped to "0 bar".
1. Slightly loosen both nuts (2) at the tie rod so that the
remaining pressure can escape completely.
2. As soon as the pressure is down to “0 bar”, tighten the nuts
(2) again.
1
Fig. 71: Loosen coupling
NOTE!
Clean mortar hoses immediately
3. Cover coupling connections with tear-proof film.
4. Loosen cam leaver (1) and hose connections.
5. Dislodge the blockage by tapping or shaking at the place
where the blockage is located.
6. If required, insert a rinsing hose into the mortar hose and
flush out the material (PFT rinsing hose art. no. 00113856).
3
7
4
6