Mixing Pump RITMO XL FU 230V Overview – Operation
Feeding machine with factory dry material
2019-12-11
31
28 Feeding machine with factory dry material
Fig. 44: Sack
Depending on the equipment, the machine can be fed with sacks,
with transfer hood or injection hood.
Feeding with sacked materials:
DANGER!
Danger of injury at sack splitter!
Sharp edges give rise to danger of injury at the sack
splitter.
– Wear safety gloves.
Fig. 45: Transfer hood
Feeding with transfer hood:
DANGER!
Do not open the transfer hood when the machine is in
operation. Switch off the main switch before opening,
and disconnect power supply.
NOTE:
Feed the mixing pump RITMO XL only with material.
To do this, pull out the dummy connector or switch
off machine via air pressure control. Start work only
when the filling level indicator shows Full.
Fig. 46: Injection hood
Feeding with injection hood:
Install the injection hood on the adapter injection hood RITMO XL
complete Art. No. 00201619 (accessory).
Ensure that the connection is tight.
DANGER!
Do not open the machine during compressed air
delivery. Switch off the main switch before opening,
and disconnect power supply.
29 Monitoring the machine
DANGER!
Access by unauthorised persons!
The machine must be operated only if monitored.