![PFT RITMO XL FU Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/pft/ritmo-xl-fu/ritmo-xl-fu_operating-instructions-manual_1535721019.webp)
Mixing Pump RITMO XL FU 230V Overview – Operation
Operating modes
2019-12-11
19
15 Operating modes
15.1 Selector switch pump motor
Fig. 16:
Operating modes pump motor
The pump motor can be operated in three operating modes:
Selector switch position “0”:
The machine is switched off.
Selector switch right (toggle):
The machine starts when the main switch and the control
voltage is switched on:
Selector switch left (momentary contact):
The pump motor runs backwards, thus the pump is relaxed
while all other functions are locked.
15.2 Selector switch pressure booster pump
Fig. 17:
Operating modes
water pump
The pressure booster pump can be operated in three different operating
modes:
Selector switch position “0”:
Water pump is switched off, e.g. if the water pressure is continuously at
2.5 bar.
Selector switch right:
Water pump is running in sync with the mixing pump (automatic mode).
Selector switch left:
The water pump runs continuously in position “manual” (e.g. for
cleaning the hoses).