![PFT RITMO XL FU Operating Instructions Manual Download Page 30](http://html1.mh-extra.com/html/pft/ritmo-xl-fu/ritmo-xl-fu_operating-instructions-manual_1535721030.webp)
Mixing Pump RITMO XL FU 230V Overview – Operation
Mortar pressure manometer
30
2019-12-11
25.2
Soaking of the mixing section
3
2
1
Fig. 41: Soaking
NOTE!
As a rule, the pump has to be soaked. The
soaking process permits an easier start-up of the
pump.
1. Connect the water hose (1) to the mixing tube.
2. Remove the blind cover (2) from the lower water nozzle.
3. Press the water supply button (3).
4. Release the water supply button (3) as soon as water
emerges from the lower water nozzle.
5. Screw the blind cover (2) back on the lower water nozzle.
26 Mortar pressure manometer
Fig. 42: Mortar pressure manometer
DANGER!
Too high operating pressure!
Machine
components
can
bounce
uncontrollably and injure the operator.
Hence:
– Do not operate the machine without a
mortar pressure manometer.
– Use only mortar hoses with an approved
operating pressure of min. 40 bar.
– The burst pressure of the mortar hose
must reach at least 2.5 times the value
of the operating pressure.
27 Hazardous dusts
Fig. 43: Dust protection
Warning!
In the long term, inhaled dust can lead to lung
damage or have other adverse health effects.
NOTE!
The machine operator or the person working in
the dusty area always has to wear a dust
protection mask when filling the machine!
The rules of the Committee on Dangerous
Substances (AGS) can be found under Technical
Rules for Dangerous Substances (TRGS 559).