36 Measures in case of power cut
36.1 Main switch to position “0“
Fig. 64: Selector switch position “0”
1. Close the air tap at the spraying gun.
2. Turn the main switch to position "0".
3. Switch off the air compressor.
4. Let qualified personnel check the power supply.
36.2 Relieve mortar pressure
2
1
Fig. 65: Check mortar pressure
DANGER!
Overpressure on the machine!
When opening machine parts they can open
in an uncontrolled manner and injure the
operator.
Open machine only when the pressure is at
"0 bar".
DANGER!
Risk of injury from discharged mortar!
Discharged mortar may lead to injuries to
eyes and face.
Therefore:
Never look into the spraying device.
Always wear protective goggles.
Always position yourself in such a way that
you are not hit by the mortar being
discharged.
1. Open the air tap at the spraying gun.
2. Check the mortar pressure gauge (1) if the mortar
pressure has lowered to "0 bar". If required relieve the
mortar pressure by lightly loosening the nuts (2). In doing
so, cover the work area with film.
3. Firmly tighten the nuts again.