Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Setting values / settings
68
2021-02-10
48 Setting values / settings
48.1.1 Setting value of water pressure switch
Fig. 114
: Water pressure switch
Switching on
the machine
Switching off
the machine
Water
2.2 bar
1.9 bar
48.1.2 Setting value of air pressure switch
Fig. 115: Air pressure switch
Switching on
the machine
Switching off
the
machine
Air
0.9 bar
1.2 bar
48.1.3 Setting value of air compressor pressure switch
Fig. 116: Air compressor pressure switch
Switch on air
compressor
Switching off the
air compressor
Compressor
2.5 bar
3.1 bar
1. Switch the air compressor on or off at the rotary switch (1).
NOTE!
Close the ball valve (2) for continuous operation of
the air compressor.
48.2 Adjusting the level probe
1 3 2
Fig. 117: Adjusting the level probe
NOTE!
The level probe with adapter plate (1) can be
individually adjusted to the respective material
consistency by sliding it on the perforated strip (2).
1. Remove the cotter pin (3) on both sides.
2. Move the level probe (1) on the perforated strip (2) to
the desired position.
3. Secure level probe with adapter plate (1) with spring cotter (3).
1
2