Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Safety device
2021-02-10
27
Fig. 26: Emergency OFF button
NOTE!
The Emergency OFF button is used to quickly put
the machine into a safe state in case of danger or to
avert a danger.
The Emergency OFF button must lock after operation.
This immediately cuts off the energy supply to the drive elements.
Turning the Emergency OFF button returns it to its original position.
An Emergency OFF button is located on the control box door (1).
An Emergency OFF button is located on the installation cabinet (2).
WARNING!
Danger to life by disabling safety devices!
Never carry out illegal actions on safety equipment
that endanger the life or health of employees.
20.2 Position switch for pump unit
Fig. 27: Position switch
If the pump unit is released while the machine is running,
the machine is switched off via the position switch (1).
20.3 Position switch for mixing tube
Fig. 28: Position switch
If the mixing tube is released while the machine is running,
the machine is switched off via the position switch (1).
20.4 Hinge safety switch on the protective grille
Fig. 29: Hinge safety switch
If the protective grille is opened while the machine is running,
the machine is switched off via the hinge safety switch (1).
1
1
1
1
2