Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
End of work / Cleaning the machine
2021-02-10
59
Fig. 93: Mixing shaft
4. Pull off and clean the mixing tube (4) with the mixing shaft (5).
5. Lightly grease the bearing journal after cleaning.
43.6.2 Inserting the rubber mixing tube and mixing shaft
Fig. 94: Installing the parts
1. Insert cleaned rubber mixing tube with cleaned mixing shaft.
2. Close quick fasteners (1).
3. Secure the quick-release fasteners (1) with the folding pin (2).
4. Couple water hose (3) to the rubber mixing tube.
NOTE!
When installing the components, make certain
they are clean and dry.
Ensure that the metering and mixing shaft is
correctly seated.
Always keep quick-release fasteners and seals in
a clean condition. Lightly grease bearing journals
and connection points of the mixing shaft.
43.7 Cleaning the pump container
Fig. 95: Cleaning the pump container
1. Clean the pump container (2) with water jet.
2. Open the cleaning nozzle (1).
3. Collect residual material and cleaning water in a suitable
container and dispose of it properly.
43.8 Cleaning the level probe
Fig. 96: Cleaning the level probe
1. Clean the level probe (1) in the pump container regularly.
5
4
2
1
3
1
2
2
1
1