4.3 Operating requirements
Ambient conditions
Specification
Value Unit
Temperature range
2–45 °C
Relative humidity (maximum)
80 %
Operating period
Specification
Value Unit
Maximum continuous
operating period
8
hours
4.4 Output values
Pump output R7-3S
Specification
Value Unit
Pumping capacity, approx.
7-26 l/min
Max. operating pressure
30 bar
Pumping distance*,
max. at 50 mm Ø
50
m
* Recommended value, depending on conveying height, condition and version of
pump, mortar quality (composition and consistency)
5 Sound power level
Sound power level LWA
95 dB(A)
6 Vibrations
Weighted effective acceleration value to which the upper limbs are exposed = < 2.5 m/s²