30.2 Switching off the machine
Fig. 44: Switching off the machine
1. Switch off the machine, press the red pushbutton (1) so
the control voltage is “OFF”.
30.3 Coupling the water hose to the mixing tube
Fig. 45: Coupling the water hose
1. Remove the water hose (1) from the pump container
and reconnect it to the mixing tube.
30.4 Switching over the step switch
Fig. 46: Switching over the step switch
NOTE!
In general, before switching over the step switch (1)
to other operating modes, the control voltage should
be switched off via the “ON” / “OFF” operation
pushbutton (2). Then switch on the control voltage
again via the pushbutton.
31 Mortar pressure gauge
Fig. 47: Mortar pressure gauge
DANGER!
Operating pressure too high!
Machine components can fly open in an
uncontrolled manner and injure the operator.
Do not operate the machine without the mortar
pressure gauge.
Only use conveying hoses with a permissible
operating pressure of at least 40 bar.
The burst pressure of the mortar hose must be
at least 2.5 times the operating pressure.