Page 19
Master Programming Guide
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
18. Fleck Flow Meter Size (Default to Valve Type)
This program step sets the size of the Fleck flow meter.
1.0” Paddle (2750 Default)
•
1.5” Paddle (2850/2900 Default)
•
2.0” Paddle (3150 Default)
•
3.0” Paddle (3900 Default)
•
1.0” Turbine
•
1.5” Turbine
•
Generic Flow Meter
•
Use Up or Down buttons to adjust this value.
1.
Press the Extra Cycle button.
2.
19. Maximum Flow Rate
This program step sets maximum flow rate of the generic flow meter.
Press the Shift button to select the digit you want to modify.
1.
Press the Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
20. Pulses per Gallon/Liter
This program step sets the pulses per gallon/liter for generic flow meters.
Press the Shift button to select the digit you want to modify.
1.
Press the Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
21. End of Master Programming Mode