Master Programming Guide
13. Regeneration Time
This program step sets time of day for a delayed regeneration to occur, or regeneration day override.
Default U.S.:
02:00 AM
Default Metric:
02:00 HR
Use the Shift button to select the digit you want to modify.
1.
Use Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
14. Regeneration Cycle Steps
This program step programs the Regeneration Cycle step times 1 through 5. Please refer to the chart below for
regenerant flow default cycle steps and times.
15.
Auxiliary Relay Output
The next two displays are part of a series of settings used to program the optional relay output. The first setting
turns the output on/off during Regeneration only. The second turns the output on during Service only, every time a
set volume of water used has accumulated.
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Regenerant Flow
Cycle 1
Time
Cycle 2
Time
Cycle 3
Time
Cycle 4
Time
Cycle 5
Time
Down Flow
Back Wash
10
Minutes
Brine &
Slow Rinse
1 Hour
Rapid
Rinse
10
Minutes
Brine Tank Fill
12 Minutes
Pause
N/A
UF Brine Draw
Brine & Slow
Rinse
1 Hour
Backwash
10
Minutes
Rapid
Rinse
10
Minutes
Brine Tank Fill
12 Minutes
Pause
N/A
UF Fill First
Brine Tank
Fill
12
Minutes
Brine
Making
1 Hour
Brine
& Slow
Rinse
1 Hour
Back Wash
10 Minutes
Rapid
Rinse
10 Minutes
Summary of Contents for 3200NXT
Page 1: ...3200NXT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Page 25: ...Page 25 Notes...
Page 30: ...Page 30 2750 2850 3150 Input Output Wiring...
Page 31: ...Page 31 2900 3900 Input Output Wiring...
Page 34: ...Page 34 Notes...
Page 35: ...Page 35 Notes...
Page 36: ...P N 42599 Rev C 4 09...