10. Capacity Safety Factor
This program step is used to adjust the capacity of the system. This is a percentage by which the unit’s capacity is
reduced.
Range:
0 – 50% (Default = 0%)
Use the Shift button to select the digit you want to modify.
1.
Use Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
11. Feed Water (Hardness)
This program step is used to set the feed water hardness. The system will automatically calculate volume
remaining based on the Unit Capacity, Capacity Safety Factor and Feed Water Hardness entered.
U.S. Range:
1 – 199 gpg (Grains per Gallon)(Default = 15)
Metric Range:
2 – 199 Degrees (Default = 30)
Use the Shift button to select the digit you want to modify.
1.
Use Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
12. Regeneration Day Override
This program step sets the maximum amount of time (in days) the unit can be In Service without a Regeneration.
Default:
OFF
Range:
1 - 99 Days
NOTE:
If “On,” the screen for regeneration time will display.
Use the Shift button to select the digit you want to modify.
1.
Use Up or Down buttons to adjust this value.
2.
Press the Extra Cycle button.
3.
Master Programming Guide
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Summary of Contents for 3200NXT
Page 1: ...3200NXT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Page 25: ...Page 25 Notes...
Page 30: ...Page 30 2750 2850 3150 Input Output Wiring...
Page 31: ...Page 31 2900 3900 Input Output Wiring...
Page 34: ...Page 34 Notes...
Page 35: ...Page 35 Notes...
Page 36: ...P N 42599 Rev C 4 09...