Network/Communication Cables & Connections
The number of network/communication cables needed for setup is one less than the total number of valves.
Two-Unit System:
One network/communication cable
Three-Unit System:
Two network/communication cables
Four-Unit Systems:
Three network/communication cables
3200NXT Circuit Board
1
2
Lock Regen Ground
Use either a CAT3 or CAT5 Network/Communication cable.
1. Connect the network/communication cable first before programming.
2. The maximum cable lenth between timers is 100 feet.
3. Connect each unit together from one communication port to the next communication port. It does not
matter which one goes to the next one.