Last printed 9/3/2002
6
4
……………………………. Key
5
……………………………. - Sense
6
……………………………. - Excitation
7
……………………………. + Signal
8
……………………………. + Excitation
NOTE: If a four wire hook up is used, short connector pins 7 and 8 together.
CONNECTING THE 7600/4 IN WASHDOWN APPLICATIONS:
Open the 7600/4 enclosure by removing the screws holding on the back plate. Carefully
remove the back plate from the indicator. The main circuit board is mounted to the back plate.
On the main circuit board, locate the load cell terminal block labeled P11. A white dot on the
circuit board denotes the location of pin #1 on the terminal block. Insert the scale platform cable
through the watertight Heyco bushing supplied on the indicator housing and feed it up to the load
cell terminal block. Insert the wires from the load cell cable into the terminal block using a small
screwdriver to tighten the connection for each wire. The following chart shows the proper
wiring for the terminal block.
WIRE COLOR
FUNCTION
TERMINAL
(Pennsylvania Scale Platforms)
LOCATION
GREEN
+ SIGNAL
# 1
WHITE
- SIGNAL
# 2
SHIELD
SHIELD
# 3
-------
-------
# 4
BLACK
- SENSE
# 5
BLUE
- EXCITATION
# 6
RED
+ SENSE
# 7
BROWN
(or ORANGE)
+ EXCITATION
# 8
A four wire load cell hook up may be used but is not recommended. If a four wire hook
up is necessary, short the + EXCITATION to the + SENSE on the terminal block.