42
Model 7600 40 Piece Weight Storage and Recall
This version 7600 is designed to allow storage and recall of up to 40 piece weights with a 6 digit
numeric ID.
NOTE: For this model the 2
nd
Base option is not available.
Operating Instructions:
Store Piece Weights Using Sample:
1. Select the unit of measure to establish the piece weight in by pressing the UNITS button
to cycle through the primary and secondary-weighing units. Default is LBS for primary,
KG for secondary.
2. Press the SAMPLE button repeatedly, until the desired sample size is displayed OR use
the numeric keypad to enter a unique sample size. Place the sample on the scale all at
once. The scale will determine the piece weight and enter count mode.
3. Press the STORE/8 button and enter the ID number for this piece weight. The scale will
alternately display ID and the last ID number used. Key in the new ID Number and
ENTER. The scale will now display the piece weight established through sampling in
step 2. To use this piece weight press the ENTER button.
4. The piece Weight is now stored in memory and may be recalled.
Store A Manually Entered Piece Weight:
1. Select the unit of measure to establish the piece weight in by pressing the UNITS button
to cycle through the primary and secondary-weighing units. Default is LBS for primary,
KG for secondary.
2. Press the PIECE WEIGHT Button, key in the piece weight and press the ENTER button.
3. Press the STORE/8 button and enter the ID number for this piece weight. The scale will
alternately display ID and the last ID number used. Key in the new ID Number and
ENTER. The scale will now display the piece weight manually entered in step 2. To use
this piece weight press the ENTER button.
4. The piece Weight is now stored in memory and may be recalled.
Recall A Piece Weight:
1. Press the ID/5 button, key the ID number and press the ENTER. The display will flash
RECALL then go into count mode using the piece weight that was previously stored.
2. If an ID number is entered that is not stored in memory the display will flash NOT
FOUND and return to normal weighing or counting mode.
To Clear A Piece Weight:
1. Press the STORE/8 button, key the ID number and press the ENTER. The display will
flash PC and the Piece Weight in memory. Press the “.“ (decimal) button and ENTER.
The Piece Weight and ID number is now removed from the scale memory.
Note:
For this Model the part ID functions as described above. For more information on