Relion 1900e/2900e Manual
91
Revision 1.3
10. On-board Connector/Header Overview
This section identifies the location and pin-out for on-board connectors and headers of the server board that
provide an interface to system options/features, on-board platform management, or other user accessible
options/features.
10.1
Power Connectors
The server board includes several power connectors that are used to provide DC power to various devices.
10.1.1
Main Power
Main server board power is supplied from two slot connectors, which allow for one or two (redundant) power
supplies to dock directly to the server board. Each connector is labeled as “MAIN PWR 1” or “MAIN PWR 2”
on the server board. The server board provides no option to support power supplies with cable harnesses.
In a redundant power supply configuration, a failed power supply module is hot-swappable. The following
tables provide the pin-out for both “MAIN PWR 1” and “MAIN PWR 2” connectors.
Table 26. Main Power (Slot 1) Connector Pin-out (“MAIN PWR 1”)
Signal Name
Pin # Pin#
Signal Name
GROUND
B1
A1
GROUND
GROUND
B2
A2
GROUND
GROUND
B3
A3
GROUND
GROUND
B4
A4
GROUND
GROUND
B5
A5
GROUND
GROUND
B6
A6
GROUND
GROUND
B7
A7
GROUND
GROUND
B8
A8
GROUND
GROUND
B9
A9
GROUND
P12V
B10
A10 P12V
P12V
B11
A11 P12V
P12V
B12
A12 P12V
P12V
B13
A13 P12V
P12V
B14
A14 P12V
P12V
B15
A15 P12V
P12V
B16
A16 P12V
P12V
B17
A17 P12V
P12V
B18
A18 P12V
P3V3_AUX: PD_PS1_FRU_A0 B19
A19 SMB_PMBUS_DATA_R
P3V3_AUX: PD_PS1_FRU_A1 B20
A20 SMB_PMBUS_CLK_R
P12V_STBY
B21
A21
FM_PS_EN_PSU_N
FM_PS_CR1
B22
A22 IRQ_SML1_PMBUS_ALERTR2_N
P12V_SHARE
B23
A23 ISENSE_P12V_SENSE_RTN
TP_1_B24
B24
A24 ISENSE_P12V_SENSE
FM_PS_COMPATIBILITY_BUS B25
A25 PWRGD_PS_PWROK
Summary of Contents for Relion 1900e
Page 2: ...Relion 1900e 2900e Manual Revision 1 3 April 2016 Intel Server Boards and Systems...
Page 11: ...Relion 1900e 2900e Manual x Revision 1 3 Figure 36 Relion 1900e 149 Figure 37 Relion 2900e 152...
Page 14: ...Relion 1900e 2900e Manual Revision 1 3 xiii This page is intentionally left blank...
Page 15: ......