Relion 1900e/2900e Manual
133
Revision 1.3
Table 59. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1 - EvMRev
=04h (IPMI2.0 format)
Byte 2 – Sensor Type
=DCh (OEM)
Byte 3 – Sensor Number
(Node Manager Health sensor)
Byte 4 – Event Dir | Event Type
[0:6] – Event Type
= 73h (OEM)
[7] – Event Dir
=0 Assertion Event
Byte 5 – Event Data 1
[0:3] – Health Event Type
=02h – Sensor Node Manager
[4:5]=10b – OEM code in byte 3
[6:7]=10b – OEM code in byte 2
Byte 6 – Event Data 2
[0:3] – Domain Id (Currently, supports only one domain,
Domain 0)
[4:7] – Error type
=0-9 - Reserved
=10 – Policy Misconfiguration
=11 – Power Sensor Reading Failure
=12 – Inlet Temperature Reading Failure
=13 – Host Communication error
=14 – Real-time clock synchronization failure
=15 – Reserved
Byte 7 – Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <InletSensorAddress>
Otherwise set to 0.