Relion 1900e/2900e Manual
Revision 1.0
110
Color
State
Criticality
Description
Amber ~1 Hz
blink
Non-critical -
System is
operating in a
degraded state
with an
impending
failure warning,
although still
functioning
Non-fatal alarm – system is likely to fail:
•
Critical threshold crossed – Voltage, temperature
(including HSBP temp), input power to power supply,
output current for main power rail from power supply
and PROCHOT (Therm Ctrl) sensors.
•
VRD Hot asserted.
•
Minimum number of fans to cool the system not present
or failed
•
Hard drive fault
•
Power Unit Redundancy sensor – Insufficient resources
offset (indicates not enough power supplies present)
•
In non-sparing and non-mirroring mode if the threshold
of correctable errors is crossed within the window
Amber Solid on
Critical, non-
recoverable –
System is
halted
Fatal alarm – system has failed or shutdown:
•
CPU CATERR signal asserted
•
MSID mismatch detected (CATERR also asserts for this
case).
•
CPU 1 is missing
•
CPU Thermal Trip
•
No power good – power fault
•
DIMM failure when there is only 1 DIMM present and
hence no good memory present.
•
Runtime memory uncorrectable error in non-redundant
mode.
•
DIMM Thermal Trip or equivalent
•
SSB Thermal Trip or equivalent
•
CPU ERR2 signal asserted
•
BMC/Video memory test failed. (Chassis ID shows
blue/solid-on for this condition)
•
Both uBoot BMC FW images are bad. (Chassis ID shows
blue/solid-on for this condition)
•
240VA fault
•
Fatal Error in processor initialization:
o
Processor family not identical
o
Processor model not identical
o
Processor core/thread counts not identical
o
Processor cache size not identical
o
Unable to synchronize processor frequency
o
Unable to synchronize QPI link frequency
•
Uncorrectable memory error in a non-redundant mode
Summary of Contents for Relion 1900e
Page 2: ...Relion 1900e 2900e Manual Revision 1 3 April 2016 Intel Server Boards and Systems...
Page 11: ...Relion 1900e 2900e Manual x Revision 1 3 Figure 36 Relion 1900e 149 Figure 37 Relion 2900e 152...
Page 14: ...Relion 1900e 2900e Manual Revision 1 3 xiii This page is intentionally left blank...
Page 15: ......