Power Supply DC Output Specification
13.2.1
Output Power/Currents
The following tables define the minimum power and current ratings. The power supply must meet both
static and dynamic voltage regulation requirements for all conditions.
Table 51. Minimum Load Ratings
Parameter Min Max. Peak
2, 3
Unit
12V main
0.0 62.0 70.0
A
12Vstby
1
0.0 2.1
2.4
A
Notes:
1. 12Vstby must provide 4.0A with two power supplies in parallel. The Fan may start to work when stby
current >1.5A
2. Peak combined power for all outputs shall not exceed 850W.
3. Length of time peak power can be supported is based on thermal sensor and assertion of the
SMBAlert# signal. Minimum peak power duration shall be 20 seconds without asserting the
SMBAlert# signal at maximum operating temperature.
13.2.2
Standby Output
The 12VSB output shall be present when an AC input greater than the power supply turn on voltage is
applied. There should be load sharing in the standby rail. Two PSU modules should be able to support 4A
standby current.
13.2.3
Voltage Regulation
The power supply output voltages must stay within the following voltage limits when operating at steady
state and dynamic loading conditions. These limits include the peak-peak ripple/noise. These shall be
measured at the output connectors.
Table 52. Voltage Regulation Limits
PARAMETER TOLERANCE MIN
NOM
MAX
UNITS
+12V
- 5%/+5%
+11.40 +12.00 +12.60 V
rms
+12V stby
- 5%/+5%
+11.40 +12.00 +12.60 V
rms
13.2.4
Dynamic Loading
The output voltages shall remain within limits specified for the step loading and capacitive loading specified
in the table below. The load transient repetition rate shall be tested between 50Hz and 5kHz at duty cycles
ranging from 10%-90%. The load transient repetition rate is only a test specification. The
∆
step load may
occur anywhere within the MIN load to the MAX load conditions.
Table 53. Transient Load Requirements
Output
∆
Step Load Size Load Slew Rate Test capacitive Load
+12VSB 1.0A
0.25 A/
µ
sec
20
µ
F
+12V
60% of max load 0.25 A/
µ
sec
2000
µ
F
Note
: For dynamic con12V MIN loading is 1A.
Summary of Contents for Relion 1900e
Page 2: ...Relion 1900e 2900e Manual Revision 1 3 April 2016 Intel Server Boards and Systems...
Page 11: ...Relion 1900e 2900e Manual x Revision 1 3 Figure 36 Relion 1900e 149 Figure 37 Relion 2900e 152...
Page 14: ...Relion 1900e 2900e Manual Revision 1 3 xiii This page is intentionally left blank...
Page 15: ......