PCAN-Router Pro – User Manual
56
CAN
Supported bit timing values
Prescaler (BRP)
Time Segment 1
(TSEG1)
Time Segment 2
(TSEG2)
Synch. Jump Width
(SJW)
Nominal
0 - 1023
0 - 15
0 - 8
0 - 3
Galvanic isolation
Only with transceiver PCA82C251 on request
Supplying external devices
D-Sub pin 1; 5 V, max. 100 mA
Not connected at delivery
Internal termination
Activation via switch on the board
CAN
OFF
ON
High-speed none 120
Ω
Low-speed
4.7 k
Ω
1.1
k
Ω
Single-wire
9.1 k
Ω
2.1
k
Ω
CAN ID reserved for
configuration transfer
7E7h
Listen-only mode
Programmable; not activated at delivery
Time stamp resolution
1
μ
s
Microcontroller
CPU NXP
LPC2294
Clock frequency
56 MHz
Voltages
Core: 1.8 V; I/O: 3.3 V
RAM
16 kByte (internal)
1 MByte (external)
MCU Flash
256 kByte
(240 kByte usable for custom firmware)
Firmware upload
via CAN (PCAN interface required)
3
Ohm value depending on the used transceiver module at the respective CAN channel.