PCAN-Router Pro – User Manual
33
4.
Enable the symbol entry by checking the corresponding
field
Enable
.
5.
Make sure that a CAN connection exists between the
computer and the PCAN-Router Pro, and, furthermore, that
the PPCAN-Editor 2 has access to this connection.
PPCAN-Editor 2: Display of a connection in the status bar on the bottom.
6.
With
Transmit > Send Configuration
or send the altered
configuration to the PCAN-Router Pro.
Do the following to set the time with PCAN-View and the
shipping configuration for the PCAN-Router Pro:
1.
Under Windows start the program PCAN-View.
2.
Establish a connection to the CAN bus that is connected
with the CAN channel 1.
3.
On the
Transmit
panel, insert the CAN message 7F8h with
8 data bytes for data, time, and the RTC update bit (see
example below).
Make sure that the values are hexadecimal values. Because
the message must only be received once by the PCAN-
Router Pro, no cyclic transmission is set.
Example for Monday, 2010-04-19, 11:13:00: