PCAN-Router Pro – User Manual
17
Positions of the switch blocks for CAN termination;
ON switch position is marked on the switch blocks
Termination at Switch Position
Type of Transceiver
Off
On
High-speed CAN (ISO 11898-2)
Transceiver installed by default.
none
120
Ω
between
CAN_L and CAN_H
Low-speed CAN (ISO 11898-3)
Transceiver only on request
4.7 k
Ω
for
CAN_L and CAN_H
1.1 k
Ω
for
CAN_L and CAN_H
Single-wire CAN (SAE J2411)
Transceiver only on request
9.1 k
Ω
for CAN_SW
2.1 k
Ω
for CAN_SW
7.
Put the cover back on the housing by paying attention to the
LED light guides.
8.
Screw the four screws at the upper corners of the housing
on the front and back side.
9.
Screw the two screws at the lower corners of the front
cover.
10.
Restart the device by connecting power supply again.
After the restart, the internal termination for the respective
CAN channel is active.
2
Both switches of a switch block