Technical Specifications
Connectors
Power
1 x Phoenix mating connector, 2-pole, pitch 3.81 mm
(Phoenix Contact MC1.5/2-STF-3.81 – 1827703)
CAN
4 x D-Sub (m), 9 pins
Pin assignment according to specification CiA
®
303-1
Power Supply
Operating voltage
12 V DC, 8 - 27 V possible
Current consumption
Idle:
65 mA at 12 V
Maximum:
130 mA at 8 V
95 mA at 12 V
70 mA at 27 V
Power-down: 470
μ
A
Protection
±1 kV surge protection
- 40 V reverse polarity protection
±4 kV ESD protection
Wake-up voltage
2 V to 7.5 V DC at pin 4 of D-Sub connector 3 and 4
Wake-up duration
165 ms
RTC backup supply
Button cell CR1620 3.0 V
Power saving modes
Power-down mode with 470
μ
A
CAN
Protocols on OSI layer 2
CAN 2.0 A/B
Physical transmission
ISO 11898-2 (High-speed CAN)
Transceiver PCAN-Transceiver
TJA1041
(
IPEH-001001)
Other transceivers on
request
PCAN-Transceiver PCA82C251
(
IPEH-001002)
PCAN-Transceiver MAX3057-ISO
(IPEH-001003)
PCAN-Transceiver TH8056
(IPEH-001004)
PCAN-Transceiver TJA1055 (IPEH-001005)
CAN bit rates
Nominal: 40 kbit/s - 1 Mbit/s
Controller
Internal CAN controllers (NXP LPC2294)
Supported clock frequencies 56 MHz