Connecting cables
121
SmartNode 1000 and 2000 Series Getting Started Guide
7 • SmartNode 2400 installation
Figure 77. Connecting an E1 PRI port to an NT
Figure 78. E1 crossover cable
Installing the IC-T1V interface card cables
The PRI is usually connected to a PBX or telco switch—local exchange (LE). The type and pin outs of these
devices vary depending on the manufacturer. In most cases, a straight-through RJ-45 to RJ-45 can be used to
connect the PRI (see
table 40
for IC-T1V card port pin-out listing) with a PBX (an NT) (see
figure 79
). A
cross-over cable is required to connect to an LE, as illustrated in
figure 80
.
The Interconnecting cables shall be acceptable for external use and shall be
rated for the proper application with respect to voltage, current, anticipated
temperature, flammability, and mechanical serviceability
SLOT
2
SLOT
3
SLOT
1
NT
RJ-48C, male
TX Ring
TX Tip
TX Shield
RX Ring
RX Tip
RX Shield
1
2
3
4
5
6
RJ-48C, male
1
2
3
4
5
6
Summary of Contents for 1000
Page 12: ...Compliance Information SmartNode 1000 and 2000 Series Getting Started Guide 12 Compliance...
Page 52: ...2 Product Overview SmartNode 1000 and 2000 Series Getting Started Guide 52...
Page 62: ...3 Planning the installation SmartNode 1000 and 2000 Series Getting Started Guide 62...
Page 70: ...4 SmartNode 1200 installation SmartNode 1000 and 2000 Series Getting Started Guide 70...
Page 82: ...5 SmartNode 1400 installation SmartNode 1000 and 2000 Series Getting Started Guide 82...
Page 92: ...6 SmartNode 2300 installation SmartNode 1000 and 2000 Series Getting Started Guide 92...
Page 110: ...7 SmartNode 2400 installation SmartNode 1000 and 2000 Series Getting Started Guide 110...
Page 126: ...8 Line power module installation SmartNode 1000 and 2000 Series Getting Started Guide 126...
Page 134: ...9 Interface card installation SmartNode 1000 and 2000 Series Getting Started Guide 134...
Page 151: ...151 Chapter 11 Monitoring Status Chapter contents Status LEDs 153...
Page 152: ...11 Monitoring Status SmartNode 1000 and 2000 Series Getting Started Guide 152...
Page 154: ...11 Monitoring Status SmartNode 1000 and 2000 Series Getting Started Guide 154 Status LEDs...
Page 156: ...12 Contacting Patton for assistance SmartNode 1000 and 2000 Series Getting Started Guide 156...
Page 160: ...A Specifications SmartNode 1000 and 2000 Series Getting Started Guide 160...
Page 166: ...B Cabling SmartNode 1000 and 2000 Series Getting Started Guide 166...
Page 175: ...T1 PRI 175 SmartNode 1000 and 2000 Series Getting Started Guide B Cabling...
Page 176: ...B Cabling SmartNode 1000 and 2000 Series Getting Started Guide 176 T1 PRI...
Page 178: ...C Port pin outs SmartNode 1000 and 2000 Series Getting Started Guide 178...