T1/E1 Port Information table
254
Models 2616RC, 3096RC & 3196RC Admin Reference Guide
17 • System
Figure 139. T1/E1 port information
T1/E1 Port Information table
The
T1/E1 Port Information
table (see
figure 139
) displays status information in three categories:
•
Configure
—WAN port numbers are displayed as hyperlinks. Clicking link displays a WAN Circuit Config-
uration Link window for configuring a WAN port.
•
Circuit ID
—The name defined for the WAN circuit.
•
Status
—Shows the operating status of the WAN circuit.
Note
WAN port status color indicators show the state of each T1/E1 WAN
port.The status indication symbols (see
figure 137
on page 252) are
defined as follows:
•
Green square—Functioning properly and no alarms are present.
•
Flashing red star—A critical (severity 4) alarm has been detected.
•
Orange exclamation mark—A major (severity 5) alarm has been
detected.
•
Yellow triangle—A minor (severity 6) alarm has been detected.
•
Blue square—The circuit is undergoing loopback diagnostics.
•
Gray circle—Unused; not activated. The port is not configured
for operation.
For full details on the WAN circuit parameters, refer to chapter 20,
“T1/E1 Link”
on page 285.